Home->PCM for Li-ion/Li-Polymer Battery Packs ->For 11S~13S Packs (40.7V~48.1V)-> For 13S Packs (48.1V)

Battery Protection Circuit Module (BMS/PCM) for 13S 48.1V Li-ion/Li-Polymer Battery Packs

Part number: HCX-D1007

Features and Benefits

1.Protection Circuit Board for 48.1V 13S Li-ion and Li-Polymer battery pack;

2.PCM applies for 13 cells Li-ion/Li-Polymer battery pack with E-Switch integrated, E-Switch can totally turn off the output;

3.To prevent the battery packs from overcharge,overdischarge,over current, over temperature ,short circuit ;

4.With cell balance/equilibrium function;

5.Compatible with both Li-ion and Li-Polymer cells; 

6.How balancing function works? After battery pack is fully charged. PCM will detect each cell's voltage and trim higher voltage down until other cells reach the same voltage level. Therefore, it helps cells have longer service life.

7.PCM comes with all the voltage detection wires and connectors.

Specifications

 

Item

Contents

Criteria (Adjustable)

1

Model

HCX-D805 / SH367108 038XY-AAA

13S-35A working current

2

Voltage

Charging voltage

54.6V

3

Current

Maximal continuous charging current

5A

Maximal continuous discharging current

35A

Current consumption

60μA

4

Overcharge Protection

Over charge detection voltage

4.25±0.025V (Programmable)

Over charge detection delay time

0.5-1.5S

Over charge release voltage

4.25±0.05V (Programmable)

5

Over Discharge Protection

Over discharge detection voltage

2.7±0.08V (Programmable)

Over discharge detection delay time

0.5-1.5S

Over discharge release voltage

3.0±0.1V (Programmable)

6

Discharge

Over Current Protection

(1st Protection)

Over current detection current

R=0.5mR/70

8010A

Detection delay time

1s±200ms

Release condition

Cut load & charge to recover

7

Discharge

Over Current Protection

(2nd Protection)

Over current detection current

R=0.5mR/140

160A±15A

Detection delay time

100ms±20

Release condition (delay: 100ms)

Cut load & charge to recover

8

Charge

Over Current Protection

Over current detection current

R=0.5mR/30

20A±5A

Detection delay time

1000ms

Release condition (delay: 500ms)

Disconnect the charger

8

Short Circuit Protection

Short circuit detection current

300A (actual testing is needed)

Detection delay time

220-400us

Detection condition

Cut load/charge to recover

9

Balance

Balance voltage for single cell

/

Balance current for single cell

/

10

Temperature Protection

 

10KNTC B=3435

 

Charge Over Temp Protection

50℃±4

Discharge Over Temp Protection

70℃±4

Charge Under Temp Protection

0℃±4

discharge Under Temp Protection

0℃±4

Temp. Protection delay

2S±1S

11

Resistance

Inner resistance P- B-

5

12

Temperature

Operating temperature range

0 ~ +85°C

Storage temperature range

0 ~ +85°C

13

Size (L*W*T)

L95mm*W60mm*T13mm (including heat-sink on top of BMS)

Copyright © 2011 BesTech Power Co., Ltd.
Tel:+86 - 769 82033052     Fax:+86 - 769 82033050 # 620   E-mail:info@BesTechPower.com
Factory ShenZhen: 3F, Bldg3, Fulian Industrial Park, Heping Industrial area, Jianhui Rd, Longhua, ShenZhen, China 518109.
Factory DongGuan: 3F, Block 1, HaoYun TongYuan Science Park, Qiaojiao Middle Road #1, TangXia Town, DongGuan, China 523726.